<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Archiving and Interchange DTD with OASIS Tables with MathML3 v1.4 20241031//EN" "https://jats.nlm.nih.gov/archiving/1.4/JATS-archive-oasis-article1-4-mathml3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" dtd-version="1.4" article-type="research-article" xml:lang="en"><front><journal-meta><journal-title-group><journal-title xml:lang="ru">Известия НТЦ Единой энергетической системы</journal-title></journal-title-group><issn publication-format="print">2307-261X</issn></journal-meta><article-meta><article-categories><subj-group><subject>Other</subject></subj-group></article-categories><title-group><article-title xml:lang="ru">Выбор оптимального объема управляющих воздействий от АОПО на разгрузку защищаемого элемента с применением возможностей ПТК ЦСПА</article-title><trans-title-group xml:lang="en"><trans-title>Complex of the Centralized Emergency Control System</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author"><name-alternatives><name xml:lang="ru"><surname>Шилков</surname><given-names>Федор Валерьевич</given-names></name><name xml:lang="en"><surname>Shilkov</surname><given-names>F. V.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff1"/><xref ref-type="aff" rid="aff2"/><email>workfed@yandex.ru</email></contrib><aff-alternatives id="aff1"><aff><institution xml:lang="en">System Operator of the United Power System</institution><city xml:lang="en">Moscow</city><country xml:lang="en">Russia</country></aff></aff-alternatives><aff-alternatives id="aff2"><aff><institution xml:lang="ru">Филиал АО «СО ЕЭС» «Объединенное диспетчерское управление энергосистемы Центра»</institution><city xml:lang="ru">Москва</city><country xml:lang="ru">Россия</country></aff></aff-alternatives></contrib-group><pub-date pub-type="epub" iso-8601-date="2026-09-09"><day>09</day><month>09</month><year>2026</year></pub-date><issue>96</issue><fpage>42</fpage><lpage>46</lpage><self-uri xlink:href="https://www.ntcees.ru/departments/NTO/sections/sb96/96_6.php" xlink:title="https://www.ntcees.ru/departments/NTO/sections/sb96/96_6.php">https://www.ntcees.ru/departments/NTO/sections/sb96/96_6.php</self-uri><abstract xml:lang="ru"><p>Централизованная система противоаварийной автоматики (ЦСПА) третьего поколения способна выполнять выбор управляющих воздействий (УВ) по данным текущего режима и с учетом существующих токовых ограничений. Рассматривается применение ЦСПА для расчета объема УВ на разгрузку станции с учетом действия автоматики ограничения перегрузки оборудования (АОПО). В качестве примера проанализирована работа существующей неадаптивной АОПО ВЛ 330 кВ Калининская – Новая в трех характерных режимах. Выявлен положительный эффект от применения ЦСПА и адаптивной АОПО, заключающийся в исключении случаев избыточного срабатывания автоматики, ошибочного несрабатывания и уменьшении требуемых объемов УВ.</p></abstract><abstract xml:lang="en" abstract-type="summary"><p>The third-generation Centralized Emergency Control System (CECS) is capable of selecting control actions (CAs) based on current operating conditions and taking into account existing current limitations. This paper considers the application of the CECS to calculate the volume of CAs for unloading a power plant, taking into account the operation of Equipment Overload Protection Automation (EOPA). As an example, the operation of the existing non adaptive EOPA for the 330 kV Kalininskaya–Novaya overhead line (OHL) is analyzed in three typical operating modes. A positive effect of using the CECS and adaptive EOPA has been identified. It consists in eliminating cases of excessive actuation of the automation, erroneous failure to actuate, reducing the required volume of control actions.</p></abstract><kwd-group xml:lang="ru"><kwd>ЦСПА</kwd><kwd>противоаварийная автоматика</kwd><kwd>АОПО</kwd><kwd>управляющие воздействия</kwd><kwd>энергосистема</kwd></kwd-group><kwd-group xml:lang="en"><kwd>CECS</kwd><kwd>emergency control automation</kwd><kwd>EOPA</kwd><kwd>control actions</kwd><kwd>power system</kwd></kwd-group></article-meta></front><back><ref-list><ref id="ref1"><mixed-citation publication-type="other" xml:lang="ru">Кощеев, Л. А. ЦСПА на базе алгоритмов нового поколения – очередной этап в развитии противоаварийного управления в энергосистемах / Л. А. Кощеев, Н. Г. Шульгинов // Известия НТЦ Единой энергетической системы. – 2013. –№ 1 (68). – С. 7–14.</mixed-citation></ref><ref id="ref2"><mixed-citation publication-type="other" xml:lang="ru">Чувашева, Н. Ш. Выбор управляющих воздействий по общим пусковым органам двух смежных комплексов ПТК ЦСПА / Н. Ш. Чувашева //Известия НТЦ Единой энергетической системы. – 2026. – № 1 (94). – С. 26–30.</mixed-citation></ref><ref id="ref3"><mixed-citation publication-type="other" xml:lang="ru">ГОСТ Р 59384-2025 Единая энергетическая система и изолированно работающие энергосистемы. Релейная защита и автоматика. Автоматическое противоаварийное управление режимами энергосистем. Устройства автоматики ограничения перегрузки оборудования. Нормы и требования.– М. : Российский институт стандартизации, 2025. – 46 с.</mixed-citation></ref><ref id="ref4"><mixed-citation publication-type="other" xml:lang="ru">Особенности применения автоматики ограничения перегруза оборудования с адаптивной токовой уставкой. Примеры реализации проекта АОПО на Заинской ГРЭС и ПС Тамань / Р. В. Разумов, А. А. Петров, Д. В. Трифонов, Иванов А. В., Басаркин В. А. // Релейная защита и автоматизация. – 2016. – № 3 (24). – С. 58–64.</mixed-citation></ref><ref id="ref5"><mixed-citation publication-type="other" xml:lang="ru">ГОСТ 55105-2019 Оперативно-диспетчерское управление. Автоматическое противоаварийное управление режимами энергосистем. Противоаварийная автоматика энергосистем. Нормы и требования. – М. : Стандартинформ, 2019. – 24 с.</mixed-citation></ref><ref id="ref6"><mixed-citation publication-type="other" xml:lang="en">—</mixed-citation></ref></ref-list></back></article>
